MY relė

Rated voltageMust operate voltageMust release voltageMax. voltagePower consumption (approx.)
% of rated voltage
AC 6 V, 12 V, 24 V, 48 / 50 V 80% max 30% min. 110% 1.0 to 1.2 VA (60 Hz)
110 / 120 V, 220 / 240 V 0.9 to 1.1 VA (60 Hz)
DC 6 V, 12 V, 24 V, 48 V, 100 / 110 V 10% min. 0.9 W

Contact  ratings
Item2-pole4-pole4-pole (bifurcated)
Resistive loadInductive loadResistive loadInductive loadResistive loadInductive load
Rated load 5 A at 250 VAC 2 A at 250 VAC 3 A at 250 VAC 0.8 A at 250 VAC 3 A at 250 VAC 0.8 A at 250 VAC
5 A at 30 VDC 2 A at 30 VDC 3 A at 30 VDC 1.5 A at 30 VDC 3 A at 30 VDC 1.5 A at 30 VDC
Rated carry current 10 A 5 A
Max. switching voltage 250 VAC, 125 VDC 250 VAC, 125 VDC
Max. switching current 10 A 5 A
Max. switching power 2,500 VA,
300 W
1,250 VA,
300 W
1,250 VA, 150 W 500 VA, 150 W 1,250 VA, 150 W 500 VA, 150 W
Failure rate
(reference value)
5 VDC at 1 mA 1 VDC at 1 mA 1 VDC at 0.1 mA
Mechanical life AC: 50,000,000 operations min., DC: 100,000,000 operations min. 20,000,000 operations min.
Electrical life 500,000 operations min. 200,000 operations min. 100,000 operations min.

Technical data
Operating time 20 ms max.
Release time 20 ms max.
Dielectric strength 2,000 VAC
Ambient temperature Operating: -55 °C to 70 °C (no icing)
Size in mm 28Hx21.5Wx36D

 

Daugiau .... PDF>>




  UAB "KEMEK Engineering" Mokslininkų g. 6A, LT-08412 Vilnius